Siglent SNA6000A Series Vector Network Analyzer

Siglent SNA6000A Series Vector Network Analyzer


Specifications
Details

Siglent SNA6000A Series Vector Network Analyzer

Frequency Range
100 kHz-26.5 GHz

Ports
2/4

Dynamic range
135 dB
 

Product Introduction
SNA6000A series is a high-end vector network analyzer of SIGLENT Technology, which has a measuring frequency as high as 26.5 GHz and supports comprehensive measurement of 4-port S parameters. Its powerful differential measurement and time domain analysis capabilities make it stand out in the test of high frequency devices. Support a variety of calibration methods and limit test functions to ensure the accuracy and reliability of measurement results.

Key Features
  • Frequency Range:100 kHz~26.5 GHz
  • Dynamic Range:135 dB
  • Range of IFBW:1 Hz~10 MHz
  • Setting range of output level:-60 dBm ~ +20 dBm
  • 4-port models include standard second source
  • Jumpers / DRA (Source, Ref and Meas) standard on SNA61xxA models
 

Product advantage

High Dynamic Range and Precision

High dynamics enable more precise and reliable measurements, which is of great importance in research, development and production. The SNA6000A impresses with a dynamic range of over 135 dB, which makes it ideal for the detailed analysis of weak signals, even when they occur alongside stronger signals. This makes the analyzer ideal for measuring filters with low insertion loss and high stopband attenuation. In addition, high dynamics help to minimize signal distortion, which improves signal integrity. It also increases calibration accuracy, especially in scenarios where external influences such as cables or adapters must be minimized.

Spectrum Analyzer for Component Characterization
The integration of a spectrum analysis function into a vector network analyzer (VNA) opens up expanded possibilities, especially in the development and testing of high-frequency amplifiers, oscillators and communication systems. This extension is also available as an option namely SNA6000-SA. It allows precise analysis of harmonics, intermodulation products and other nonlinear effects, while simultaneously optimizing signal quality and bandwidth utilization in communication applications. The combination of VNA and spectrum analysis in one device not only offers space and cost-saving advantages, but also enables deeper and more comprehensive signal characterization.

Simple, Fast and Accurate Pulsed-RF Measurement
The SNA6000A can also be extended to include the ability to perform pulsed measurements, which is particularly advantageous when characterizing high-frequency components under real operating conditions, such as in radar and communication systems. This measurement method makes it possible to analyze the behavior of components with short pulses, precisely evaluate fast switching operations and optimize performance in time-critical applications.

Time Domain Analysis
To be able to perform time domain analysis the options SNA6000-TDA and SNA6000-TDR are available. The Time Domain Reflectometry functions extend the VNA to include the ability to comprehensively diagnose and characterize signal paths, lines and cables. In addition, eye diagrams can be created, which are crucial for evaluating signal integrity in digital communications. The combination of TDR and VNA also enables the analysis of jitter, which is essential for investigating the temporal stability of signals. Both functions are of particular interest in high-speed digital development.

Extend the Power to Multiport Devices
SSM single unit can expand the output ports to 24 and can be easily integrated, greatly adapt to the automatic test system and production line scenarios. The multi-port measurement capability of VNA can improve test throughput and thereby significantly reduce device test costs. Typical applications include design, verification and production of antenna, data converter interfaces, automatic test of RF components and other devices, etc.

Advanced Calibration
Calibrating network analyzers is critical for high accuracy measurements. The SNA family supports a broad range of mechanical and electronic calibration kits with the frequency up to 26.5 GHz for both general purpose and precision-level requirements and offers advanced calibration methods to enhance ease-of-use while providing best-in-class accuracy. SIGLENT protects your investment by supporting the import of calibration kits from other manufacturers and customer-defined calibration kits.
 

Product parameter
Frequency Range
100 kHz - 13.5 GHz, 100 kHz - 26.5 GHz
Ports
2, 4
Frequency Resolution
1 Hz
Level Resolution
0.05dB
Range of IFBW
1 Hz-10 MHz
Setting range of output level
-55 dBm ~ +10 dBm
Dynamic Range
135dB
Jumper
/, Yes
Output Frequency Resolution
1 Hz
Types of calibration
Response calibration, Enhanced Response calibration, Full-one port calibration, Full-two port calibration, Full-three port calibration, Full-four port calibration, TRL calibration
Interface
LAN,USB Device,USB Host(USB-GPIB)
Remote control
SCPI / Labview / IVI based on USB-TMC / VXI-11/ Socket / Telnet / Webserver
Bias-Tees
Support
Display
12.1-inch touch screen
Video Output
HDMI/DVI-D/DP
Types of measurement
Scattering-parameter measurement, differential-parameter measurement, receiver measurement, time-domain parameter analysis, limit test, ripple test, impedance conversion, fixture simulation, adapter
emoval/insertion, enhanced time-domain parameter analysis (TDR), spectrum analysis, frequency offset, scalar mixer measurement, pulse measurement, Material Measurement
 

Models
Models Frequency Range Ports Frequency Resolution Level Resolution Range of IFBW Setting range of output level Dynamic Range Jumper
SNA6022A 100 kHz - 13.5 GHz 2 1 Hz 0.05dB 1 Hz-10 MHz -55 dBm ~ +10 dBm 135dB /
SNA6024A 100 kHz - 13.5 GHz 4 1 Hz 0.05dB 1 Hz-10 MHz -55 dBm ~ +10 dBm 135dB /
SNA6032A 100 kHz - 26.5 GHz 2 1 Hz 0.05dB 1 Hz-10 MHz -55 dBm ~ +10 dBm 135dB /
SNA6034A 100 kHz - 26.5 GHz 4 1 Hz 0.05dB 1 Hz-10 MHz -55 dBm ~ +10 dBm 135dB /
SNA6122A 100 kHz - 13.5 GHz 2 1 Hz 0.05dB 1 Hz-10 MHz -55 dBm ~ +10 dBm 135dB Yes
SNA6124A 100 kHz - 13.5 GHz 4 1 Hz 0.05dB 1 Hz-10 MHz -55 dBm ~ +10 dBm 135dB Yes
SNA6132A 100 kHz - 26.5 GHz 2 1 Hz 0.05dB 1 Hz-10 MHz -55 dBm ~ +10 dBm 135dB Yes
SNA6134A 100 kHz - 26.5 GHz 4 1 Hz 0.05dB 1 Hz-10 MHz -55 dBm ~ +10 dBm 135dB Yes

View more about Siglent SNA6000A Series Vector Network Analyzer on main site