Details
Siglent SDS7000A Series Digital Storage Oscilloscope
Bandwidth
8 GHz
Real time sampling rate
20 GSa/s
Channels
4 + EXT
Product Introduction
SDS7000A series, as the new flagship oscilloscope products of Siglent Technology, the maximum bandwidth is increased to 6GHz, the rise time is only 58ps, which is more than twice as fast as the oscilloscope with 4GHz bandwidth, and it can support the measurement of signals such as MIPI-DPHY, DDR2/DDR3, USB2.0, SATA1, DDR1/2/3 and so on, which makes the application scenarios more diversified; and it also adopts the Meanwhile, it adopts a new 15.6-inch high-definition touch screen and supports split-screen display function, which brings a brand-new measurement experience.
Key Features
Product advantage
Restore the signal perfectly
The sampling rate of 20 GSa/s eliminates signal distortion. With a long storage depth of up to 1 Gpts/ch, capture complete signal sequences for up to 50 millisec at max sampling rate without any gaps. Utilize search and navigate or history tools to analyze the entire stored trace. Each sample utilizes the 12-bit ADC, limiting the quantization error, which can help engineers to observe the details of the waveform clearly and measure the waveform accurately.
Real-Time Spectrum Analysis (RTSA)
Equipped with RTSA and digital down-conversion (DDC) technologies, the SDS7000A supports up to 1 GHz Real-Time analysis bandwidth. Advanced display modes include density plots, spectrum monitoring, and 3D visualizations. Compared to traditional superheterodyne spectrum analyzers, the SDS7000A offers higher bandwidth and faster signal acquisition — ideal for capturing transient events in 5G NR, 4G LTE, and Wi-Fi.
Vector Signal Analysis (SigVSA)
SDS7000A integrates vector signal analysis software SigVSA on the device. With the help of the built-in SigVSA, the oscilloscope can directly analyze the signal of DDC output data. The supported signal types range from simple BPSK to complex broadband signals, such as 4LTE, 5NR, IEEE802.11b/a/g/n/ac/ax/be and 4096QAM. In addition, the user can directly obtain the real-time waveform from the oscilloscope for analysis, and can also analyze the saved waveform data file off-line.
Eye/Jitter analysis
As the core of signal integrity analysis of high-speed systems, eye diagrams characterize high speed communication signals. The quality of the system can be evaluated by observing the influence of inter-symbol crosstalk, noise, and bandwidth. Jitter analysis characterizes the statistical distribution of small timing changes in a systems and is often used to debug digital communication systems and high-speed signal transmission. The SDS7000A series supports automatic parameter measurements for jitter and eye characterization. Easy setup and automatic measurements speed debugging and simplify engineering design testing.
Protocol consistency analysis
USB 2.0, 100Base-TX, 1000Base-T, 2.5G/5G/10GBase-T, 100Base-T1, 1000Base-T1, MIPI-DPHY protocol conformance testing are available. When the user sets up the environment according to the prompts, by using the related test fixture, the oscilloscope and related instruments can be automatically set up and related measurement, calculation, decoding and other functions will be used for testing, helping the user to complete each test project quickly and efficiently, and reports are generated automatically.
SAP5000D active differential probe(5GHz)
The SAP5000D is our highest performing active differential probe kit providing up to 5 GHz of bandwidth and low noise for detailed signal analysis. Its high input resistance and low input capacitance can ensure that the load introduced by the measurement system is minimized. SAP5000D active probe utilizes the SAPBus interface, making it suitable for oscilloscopes including the SDS5000X, SDS6000A and SDS7000A series. These probes do not need an additional external power supply and are automatically recognized by the oscilloscope.
Product parameter
Models
Bandwidth
8 GHz
Real time sampling rate
20 GSa/s
Channels
4 + EXT
Product Introduction
SDS7000A series, as the new flagship oscilloscope products of Siglent Technology, the maximum bandwidth is increased to 6GHz, the rise time is only 58ps, which is more than twice as fast as the oscilloscope with 4GHz bandwidth, and it can support the measurement of signals such as MIPI-DPHY, DDR2/DDR3, USB2.0, SATA1, DDR1/2/3 and so on, which makes the application scenarios more diversified; and it also adopts the Meanwhile, it adopts a new 15.6-inch high-definition touch screen and supports split-screen display function, which brings a brand-new measurement experience.
Key Features
- Bandwidth: 8 GHz, 6 GHz, 4 GHz, 3 GHz
- Memory depth: up to 2 Gpts/ channel
- ADC: 12-bit
- Real-time sampling rate: up to 20 GSa/s
- Waveform capture rate: up to 1,000,000 wfm/s
Product advantage
Restore the signal perfectly
The sampling rate of 20 GSa/s eliminates signal distortion. With a long storage depth of up to 1 Gpts/ch, capture complete signal sequences for up to 50 millisec at max sampling rate without any gaps. Utilize search and navigate or history tools to analyze the entire stored trace. Each sample utilizes the 12-bit ADC, limiting the quantization error, which can help engineers to observe the details of the waveform clearly and measure the waveform accurately.
Real-Time Spectrum Analysis (RTSA)
Equipped with RTSA and digital down-conversion (DDC) technologies, the SDS7000A supports up to 1 GHz Real-Time analysis bandwidth. Advanced display modes include density plots, spectrum monitoring, and 3D visualizations. Compared to traditional superheterodyne spectrum analyzers, the SDS7000A offers higher bandwidth and faster signal acquisition — ideal for capturing transient events in 5G NR, 4G LTE, and Wi-Fi.
Vector Signal Analysis (SigVSA)
SDS7000A integrates vector signal analysis software SigVSA on the device. With the help of the built-in SigVSA, the oscilloscope can directly analyze the signal of DDC output data. The supported signal types range from simple BPSK to complex broadband signals, such as 4LTE, 5NR, IEEE802.11b/a/g/n/ac/ax/be and 4096QAM. In addition, the user can directly obtain the real-time waveform from the oscilloscope for analysis, and can also analyze the saved waveform data file off-line.
Eye/Jitter analysis
As the core of signal integrity analysis of high-speed systems, eye diagrams characterize high speed communication signals. The quality of the system can be evaluated by observing the influence of inter-symbol crosstalk, noise, and bandwidth. Jitter analysis characterizes the statistical distribution of small timing changes in a systems and is often used to debug digital communication systems and high-speed signal transmission. The SDS7000A series supports automatic parameter measurements for jitter and eye characterization. Easy setup and automatic measurements speed debugging and simplify engineering design testing.
Protocol consistency analysis
USB 2.0, 100Base-TX, 1000Base-T, 2.5G/5G/10GBase-T, 100Base-T1, 1000Base-T1, MIPI-DPHY protocol conformance testing are available. When the user sets up the environment according to the prompts, by using the related test fixture, the oscilloscope and related instruments can be automatically set up and related measurement, calculation, decoding and other functions will be used for testing, helping the user to complete each test project quickly and efficiently, and reports are generated automatically.
SAP5000D active differential probe(5GHz)
The SAP5000D is our highest performing active differential probe kit providing up to 5 GHz of bandwidth and low noise for detailed signal analysis. Its high input resistance and low input capacitance can ensure that the load introduced by the measurement system is minimized. SAP5000D active probe utilizes the SAPBus interface, making it suitable for oscilloscopes including the SDS5000X, SDS6000A and SDS7000A series. These probes do not need an additional external power supply and are automatically recognized by the oscilloscope.
Product parameter
| Bandwidth 3 GHz, 4 GHz, 6 GHz, 8 GHz |
Channels 4 + EXT |
| Sampling Rate 20 GSa/s (dual-channel), 20 GSa/s @All Channels |
Vertical Resolution 12-bit |
| Memory Depth 2 Gpts/ch, 1 Gpts/ch |
Capture Rate 1,000,000 wfm/s |
| Screen Size 15.6” HD TFT-LCD with capacitive touch screen (1920*1080) |
I/O I/O:4x USB Host 3.1 Gen 1,2x USB 3.0 Host,USB 2.0 Device (USBTMC),2x 1000M LAN (VXI-11+SCPI, Telnet (5024)+SCPI,Socket (5025)+SCPI,LXI,WebServer) Display: 1x DVI-D: up to 1920x1200 @ 60Hz; 1x DP 1.2: up to 4096x2304 @ 60Hz; 1x HDMI 1.4: up to 4096x2160 @ 60Hz Audio: Mic input, Audio Output Others: External Trigger In, Aux Out (TRIG OUT,PASS/FAIL),10 MHz In,10 MHz Out |
| Measurement 60+ parameters, statistics, histogram, trend, and track supported |
Digital channel 16 digital channels. Purchase 16-channel logic analyzer probe SPL2016, which can realize 16-channel digital channel acquisition function. |
| Trigger type Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Qualified, Nth edge, Setup/hold, Delay, Serial |
Processor system Intel Core i3-8100 or better, 32GB memory, 250GB hard disk, Linux operating system. |
| Serial trigger and decode Standard:I2C,SPI,UART,CAN,LIN Optional:CAN FD,CAN XL(decode only),FlexRay,I2S,MIL-STD-1553B,SENT,ARINC 429, Manchester(decode only),USB2.0(decode only) |
Data analysis Search, Navigate, History, Mask Test, Digital Voltmeter, Counter, Waveform Histogram, Bode plot, Power Analysis, Eye/Jitter Analysis, SignalScan, Compliance Test (USB 2.0, 100Base-TX, 1000Base-T, 2.5G/5G/10GBase-T, 100Base-T1, 1000Base-T1, MIPI-DPHY), Spectrum Analyzer mode (RTSA/DDC/Sigal analysis, for A models only) |
| Waveform generator Built-in source, maximum output frequency 50 MHz. You need to purchase any waveform generator software option to use. |
Probe (Standard) SP3150A, 500 MHz, x 4 PCS |
Models
| Models | Bandwidth | Channels | Vertical Resolution | Sampling Rate | Memory Depth | Capture Rate |
|---|---|---|---|---|---|---|
| SDS7804AP | 8 GHz | 4 + EXT | 12-bit | 20 GSa/s @All Channels | 2 Gpts/ch | 1,000,000 wfm/s |
| SDS7604AP | 6 GHz | 4 + EXT | 12-bit | 20 GSa/s @All Channels | 2 Gpts/ch | 1,000,000 wfm/s |
| SDS7804A H12 | 8 GHz | 4 + EXT | 12-bit | 20 GSa/s (dual-channel) | 1 Gpts/ch | 1,000,000 wfm/s |
| SDS7604A H12 | 6 GHz | 4 + EXT | 12-bit | 20 GSa/s (dual-channel) | 1 Gpts/ch | 1,000,000 wfm/s |
| SDS7404A H12 | 4 GHz | 4 + EXT | 12-bit | 20 GSa/s (dual-channel) | 1 Gpts/ch | 1,000,000 wfm/s |
| SDS7304A H12 | 3 GHz | 4 + EXT | 12-bit | 20 GSa/s (dual-channel) | 1 Gpts/ch | 1,000,000 wfm/s |
View more about Siglent SDS7000A Series Digital Storage Oscilloscope on main site