Siglent SDS6000A Series Digital Storage Oscilloscope

Siglent SDS6000A Series Digital Storage Oscilloscope

Category: Oscilloscopes

Specifications
Details

Siglent SDS6000A Series Digital Storage Oscilloscope

Bandwidth
2 GHz

Real time sampling rate
10 GSa/s

Channels
4 + EXT
 

Product Introduction
SIGLENT’s SDS6000A series Digital Storage Oscilloscopes are available in bandwidths of 2 GHz, 1 GHz, and 500 MHz, have a sample rate of 5 GSa/s (10 GSa/s ESR) at each channel, a maximum record length of 500 Mpts, and display up to 4 analog channels + 16 digital channels mixed-signal analysis ability.

Key Features
  • Bandwidth: 500 MHz, 1 GHz, 2 GHz
  • ADC:8-bit
  • Real time sampling rate:5 GSa/s (10 GSa/s ESR) ADC per analog channel
  • Record Length up to 500 Mpts
  • Waveform capture rate up to 750,000 wfm/s (Sequence mode)
 

Product advantage

Achieve more with SDS6000A oscilloscope
  • SDS6000A comes with even more memory depth. 500 Mpts and a hardware-based zoom.
  • The sample rate is up to 5 GSa/s (10 GSa/s ESR) per channel, even when you use all four channels at the same time. No compromises.
Modern form factor balances ease-of-use and desk space
SDS6000A is easy to move around the lab and occupy small desk space. The big 12.1 inch and high resolution touch screen provides intuitive control and clear information for faster debugging.
It is also easily customized, you can choose your favorite channel traces colors, default settings, menu styles, measurement formats and so on. The faster UI response of SDS6000A makes R&D work even more pleasing.

Eye/Jitter analysis
Troubleshoot high-speed digital circuits more effectively using the Jitter Analysis option.
Delivers Eye Diagram and Jitter analysis including jitter decomposition information and more.

Excellent Operability
  • SAP1000 active probe was released with SDS5000X oscilloscope. This time SDS6000A comes with two newly designed active probes. SAP2500 is single ended via SAP2500D is 2.5 GHz differential active probe. With the Eye diagram/ Jitter analysis functions, SDS6000A is more capable in high speed circuits design and signal integrity measurements.
  • Capacitive touch screen, supports multi-touch gestures, traces can be moved or scaled efficiently by a finger touch
  • Built-in web server supports remote control over the LAN port using a web browser
  • External mouse and keyboard support
Triggering and decoding of serial protocols covering various industries
SDS6000A provides a variety of serial protocol triggering and decoding, such as I2C, SPI, UART, CAN, CAN FD, LIN, FlexRay, SENT, I2S, MIL-STD-1553B, Manchester, ARINC429, covering many industries such as embedded, automotive, audio and wireless communication.
 

Product parameter
Bandwidth
500 MHz, 1 GHz, 2 GHz
Channels
4 + EXT
Sampling Rate
5 GSa/s (10 GSa/s ESR) @ each channel
Vertical Resolution
8-bit
Memory Depth
500 Mpts/ch
Capture Rate
Normal mode: 170,000 wfm/s; Sequence mode: 750,000 wfm/s
Screen Size
12.1” HD TFT-LCD with capacitive touch screen (1280*800)
I/O
USB 3.0 Host*2, Calibration Signal: 1 kHz,3 V Square, USB 2.0 Host *2, USB 2.0 Device, LAN: 10/100MbaseT (RJ45), Micro SD Card, External Trigger, EXT: ≤1.5 Vrms, EXT/5: ≤ 7.5Vrms, Auxiliary Output: TRIG OUT(3.3 V LVCMOS), PASS/FAIL OUT(3.3 V TTL), HDMI
Measurement
60+ parameters, statistics, histogram, trend, and track supported
Data analysis
Search, Navigate, History, Mask Test, Digital Voltmeter, Counter, Waveform Histogram, Bode plot and Power Analysis, Eye/Jitter Analysis
Trigger type
Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Qualified, Nth edge, Setup/hold, Delay, Serial
Serial trigger and decode
I2C, SPI, UART, CAN, LIN
Serial trigger and decode(Optional)
CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester(decode only),ARINC429(decode only)
Digital channel
16 digital channels. Purchase 16-channel logic analyzer probe SPL2016, which can realize 16-channel digital channel acquisition function.
Waveform generator
The maximum output frequency is 25 MHz.
You need to purchase an external signal source (SAG1021I) for use.
Probe (standard)
SP3150A, 500 MHz, x 4 PCS
 

Models
Models Bandwidth Channels Vertical Resolution Sampling Rate Memory Depth Capture Rate
SDS6054A 500 MHz 4 + EXT 8-bit 5 GSa/s (10 GSa/s ESR) @ each channel 500 Mpts/ch Normal mode: 170,000 wfm/s; Sequence mode: 750,000 wfm/s
SDS6104A 1 GHz 4 + EXT 8-bit 5 GSa/s (10 GSa/s ESR) @ each channel 500 Mpts/ch Normal mode: 170,000 wfm/s; Sequence mode: 750,000 wfm/s
SDS6204A 2 GHz 4 + EXT 8-bit 5 GSa/s (10 GSa/s ESR) @ each channel 500 Mpts/ch Normal mode: 170,000 wfm/s; Sequence mode: 750,000 wfm/s
 

Configure your instrument

Standard Accessories
Probe (Standard)
Product Description
SP3150A Passive probe, 500 MHz bandwidth, 10X attenuation ratio, input impedance of 11pF || 10MΩ, with automatic identification function.
SP3050A Passive probe, 500 MHz bandwidth, 10X attenuation ratio, input impedance of 11pF || 10MΩ, with automatic identification function.
Other
Product Description
USB Cable USB-A to USB-B. Used to connect instrument to PC for communication.
wireless mouse A wireless mouse comes standard to help you improve your operating experience.
Power cord The instrument comes standard with a power cord that conforms to the national standard of the user. Additional power cords in different regions can be purchased separately.
SDS6000A Quick Start QuickStart of SDS6000A series oscilloscopes as standard.
Protective Cover Fasten on the front panel of the machine to protect the touch screen and knob to prevent the machine from being damaged by collision.

Optional Accessories
Probe
Product Description
SP6150A Passive probe, 1.5 GHz bandwidth, 10X attenuation ratio, input impedance of 1.8pF || 500Ω, with automatic identification function.
SAP2500D Active differential probe, bandwidth of 2.5 GHz, attenuation ratio of 10X, differential input impedance of 1pF || 200kΩ, offset range of 8V, SAPBus interface.
SAP2500 Active single-ended probe, bandwidth of 2.5 GHz, attenuation ratio of 10X, input impedance of 1.1pF || 1MΩ, offset range of ±12V, SAPBus interface.
SAP1000 Active single-ended probe, 1 GHz bandwidth, 10X attenuation ratio, input impedance of 1.2pF || 1MΩ, offset range of ±12V, SAPBus interface.
HPB4010 High voltage probe, DC-40 MHz bandwidth, 1000X attenuation ratio, input impedance 3pF || 100MΩ.
DPB1300 High voltage differential probe, 50 MHz bandwidth, 50X/500X attenuation ratio, maximum differential voltage ±1300V, differential input impedance 2pF || 10MΩ, BNC interface.
DPB4080 High voltage differential probe, 50 MHz bandwidth, 10X/100X attenuation ratio, maximum differential voltage 800 V, differential input impedance 1.2pF || 54MΩ, BNC interface.
DPB5150 High voltage differential probe, bandwidth of 70 MHz, attenuation ratio of 50X/500X, maximum differential voltage of ±1500V, differential input impedance of 2pF || 10MΩ, BNC interface.
DPB5150A High voltage differential probe, 100 MHz bandwidth, 50X/500X attenuation ratio, maximum differential voltage ±1500V, differential input impedance 2pF || 10MΩ, BNC interface.
DPB5700 High voltage differential probe, 70 MHz bandwidth, 100X/1000X attenuation ratio, maximum differential voltage 7000 v, differential input impedance 2.5pF || 40MΩ, BNC interface.
DPB5700A High voltage differential probe, 100 MHz bandwidth, 100X/1000X attenuation ratio, maximum differential voltage 7000 v, differential input impedance 2.5pF || 40MΩ, BNC interface.
SCP5030 Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, SAPBus interface.
SCP5030A Current probe, DC-100 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, SAPBus interface.
SCP5150 Current probe, DC-12 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 150Arms/300Apk, jaw diameter of 20mm, powered by 12V adapter.
SCP5500 Current probe, DC-2 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 500Arms/750Apk, jaw diameter of 20mm, SAPBus interface.
CPL5100 Current probe, DC-600 kHz bandwidth, attenuation ratio of 10X/100X, current range of 50mA ~ 100Apk, powered by 12V adapter.
CP4020 Current probe, DC-200 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 20Arms/60Ap-p, 9V adapter for power supply.
CP4050 Current probe, DC-1 MHz bandwidth, 2X/20X attenuation ratio, maximum input 50Arms/140Ap-p, 9V adapter power supply.
CP4070 Current probe, DC-200 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 20Arms/60Ap-p, 9V adapter for power supply.
CP4070A Current probe, DC-300 kHz bandwidth, attenuation ratio of 10X/100X, maximum input of 70Arms/200Ap-p, 9V adapter for power supply.
CP6030 Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter.
CP6030A Current probe, DC-100 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter.
CP6150 Current probe, DC-12 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 150Arms/300Apk, jaw diameter of 20mm, powered by 12V adapter.
CP6500 Current probe, DC-5 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 500Arms/750Apk, jaw diameter of 20mm, powered by 12V adapter.
SAP4000P Power rail probe, DC-4 GHz bandwidth, 1.1X attenuation ratio, input dynamic range ±600mV, offset range ±24V, SAPBus interface.
SPL2016 16-channel logic probe (hardware), sampling rate and storage depth are determined by oscilloscope, which is suitable for SIGLENT technology SDS7000A, SDS6000A, SDS6000L, SDS5000X HD, SDS5000X, SDS3000X HD, SDS2000X HD and SDS2000X Plus models.
Other
Product Description
USB arbitrary waveform generator SAG1021I (isolated) USB arbitrary waveform generator module (isolated) integrates sine wave, square wave, triangular wave, pulse wave, noise, DC and 45 kinds of built-in arbitrary waves. Users can also edit arbitrary waveforms through EasyWave PC software.
STB-3 Demo board Signals include various sine and square waves, AM, burst, and common serial bus signals.
USB-GPIB Adapter Expand the instrument’s USB interface into a GPIB interface. Using GPIB commands allows for easier execution of various operational tasks. The USB interface adheres to the USB 2.0 specification, while the GPIB interface complies with the IEEE 488.2 standard.
DF2001A The phase calibration board, used in conjunction with power analysis software, is used to calibrate the phase difference generated by the voltage and current probes during transmission.
CASE-S1 Transport protective box,suitable for SNA5000A,SDS6000A ,SSA5000A,SDS5000X and SDS3000X-HDseries.

Options
Trigger/decode Options
Product Description
SDS6000Pro-I2S I2S trigger & decode (software)
SDS6000Pro-1553B MIL-STD-1553B trigger & decode (software)
SDS6000Pro-FlexRay FlexRay trigger & decode (software)
SDS6000Pro-CANFD CAN FD trigger & decode (software)
SDS6000Pro-SENT SENT trigger & decode (software)
SDS6000Pro-Manch Manchester decode (software)
SDS6000Pro-ARINC ARINC429 decode (software)
Analysis Options
Product Description
SDS6000Pro-PA Power Analysis (software)
SDS6000Pro-EJ Eye Diagram/Jitter Analysis (software)
Bandwidth/Channel Upgrade Options
Product Description
SDS6000Pro-4BW10 500 MHz to 1 GHz bandwidth upgrade (software)
SDS6000Pro-4BW20 1 GHz to 2 GHz bandwidth upgrade (software)

View more about Siglent SDS6000A Series Digital Storage Oscilloscope on main site