Siglent SDS6000L Series Digital Oscilloscope

Siglent SDS6000L Series Digital Oscilloscope

Category: Oscilloscopes

Specifications
Details

Siglent SDS6000L Series Digital Oscilloscope

Bandwidth
2 GHz

Real time sampling rate
5 GSa/s

Channels
4/8 + EXT
 

Product Introduction
SDS6000L series oscilloscopes focus on cost performance, with a bandwidth of 500 MHz to 2 GHz, and also have excellent 12-bit vertical resolution. Combined with high sampling rate, deep storage and rich functions, such as template testing and power analysis, it is suitable for routine testing tasks in electronic design and manufacturing and meets the daily needs of most engineers.

Key Features
  • Supports up to 512 analog channels.
  • Up to 2 GHz bandwidth with 5 GSa/s (10 GSa/s ESR) sample rate at each channel
  • Record Length up to 500 Mpts
  • Low background noise, supports 0.5 mV/div to 10 V/div vertical scales
  • Waveform capture rate up to 750,000 wfm/s (Sequence mode)
  • SYNC-64 to Synchronize 64 x SDS6000L
 

Product advantage

Complete Connectivity

Interfaces include: HDMI (1280 x 800) x1, USB Host 3.0 x2, USB Host 2.0 x2, USB Device 2.0 (USBTMC) x1, 1000M LAN (VXI-11 / Telnet / Socket)x1, micro SD card x1, Auxiliary output (Pass / Fail, Trigger Out) x1, 10 MHz In x1, 10 MHz Out x1

Eye diagram and jitter analysis
The SDS6000L Series can automatically extract the embedded reference clock from serial data and create an eye diagram. Measurement on multiple eye / jitter parameters is provided and mask testing of eye diagrams is supported.

High Waveform Update Rate
The waveform update rate of SDS6000L is up to 170,000 wfm/s, which can easily capture unusual or low-probability events. In Sequence mode, the waveform capture rate can reach 750,000 wfm/s.

Flexible Multi-channel High-speed Acquisition System
· Standard sizes: 4 – channel models – 1U,8-channel models – 2U
· Multiple units are combined to create a high-speed acquisition system with up to 512 channels by being triggered with low-skew synchronization signals from the 64-channel synchronization distributor SYN64
· The host can access each unit over 1000M LAN. A complete SCPI command set as well as LabVIEW and IVI drivers are provided for easy data acquisition. The LAN port is LXI compliant
· Sample clocks are synchronized between all units in the test system by cascading the 10 MHz In and 10 MHz Out clocks in a daisy chain
 

Product parameter
Bandwidth
500 MHz, 1 GHz, 2 GHz
Channels
4 + EXT, 8 + EXT
Sampling Rate
5 GSa/s (10 GSa/s ESR) @ each channel
Vertical Resolution
8-bit
Memory Depth
500 Mpts/ch
Capture Rate
750,000 wfm/s
Digital channel
16 digital channels. Purchase 16-channel logic analyzer probe SPL2016, which can realize 16-channel digital channel acquisition function.
Waveform generator
Built-in source, maximum output frequency 25 MHz. You need to purchase any waveform generator software option to use.
 

Models
Models Bandwidth Channels Vertical Resolution Sampling Rate Memory Depth Capture Rate
SDS6208L 2 GHz 8 + EXT 8-bit 5 GSa/s (10 GSa/s ESR) @ each channel 500 Mpts/ch 750,000 wfm/s
SDS6204L 2 GHz 4 + EXT 8-bit 5 GSa/s (10 GSa/s ESR) @ each channel 500 Mpts/ch 750,000 wfm/s
SDS6108L 1 GHz 8 + EXT 8-bit 5 GSa/s (10 GSa/s ESR) @ each channel 500 Mpts/ch 750,000 wfm/s
SDS6104L 1 GHz 4 + EXT 8-bit 5 GSa/s (10 GSa/s ESR) @ each channel 500 Mpts/ch 750,000 wfm/s
SDS6058L 500 MHz 8 + EXT 8-bit 5 GSa/s (10 GSa/s ESR) @ each channel 500 Mpts/ch 750,000 wfm/s
SDS6054L 500 MHz 4 + EXT 8-bit 5 GSa/s (10 GSa/s ESR) @ each channel 500 Mpts/ch 750,000 wfm/s
 

Configure your instrument

Standard Accessories
Probe (Standard)
Product Description
SP3150A Passive probe, 500 MHz bandwidth, 10X attenuation ratio, input impedance of 11pF || 10MΩ, with automatic identification function.
Other
Product Description
USB Cable USB-A to USB-B. Used to connect instrument to PC for communication.
Power cord The instrument comes standard with a power cord that conforms to the national standard of the user. Additional power cords in different regions can be purchased separately.

Optional Accessories
Probe
Product Description
SP6150A Passive probe, 1.5 GHz bandwidth, 10X attenuation ratio, input impedance of 1.8pF || 500Ω, with automatic identification function.
SAP2500D Active differential probe, bandwidth of 2.5 GHz, attenuation ratio of 10X, differential input impedance of 1pF || 200kΩ, offset range of 8V, SAPBus interface.
SAP2500 Active single-ended probe, bandwidth of 2.5 GHz, attenuation ratio of 10X, input impedance of 1.1pF || 1MΩ, offset range of ±12V, SAPBus interface.
SAP1000 Active single-ended probe, 1 GHz bandwidth, 10X attenuation ratio, input impedance of 1.2pF || 1MΩ, offset range of ±12V, SAPBus interface.
HPB4010 High voltage probe, DC-40 MHz bandwidth, 1000X attenuation ratio, input impedance 3pF || 100MΩ.
DPB1300 High voltage differential probe, 50 MHz bandwidth, 50X/500X attenuation ratio, maximum differential voltage ±1300V, differential input impedance 2pF || 10MΩ, BNC interface.
DPB4080 High voltage differential probe, 50 MHz bandwidth, 10X/100X attenuation ratio, maximum differential voltage 800 V, differential input impedance 1.2pF || 54MΩ, BNC interface.
DPB5150 High voltage differential probe, bandwidth of 70 MHz, attenuation ratio of 50X/500X, maximum differential voltage of ±1500V, differential input impedance of 2pF || 10MΩ, BNC interface.
DPB5150A High voltage differential probe, 100 MHz bandwidth, 50X/500X attenuation ratio, maximum differential voltage ±1500V, differential input impedance 2pF || 10MΩ, BNC interface.
DPB5700 High voltage differential probe, 70 MHz bandwidth, 100X/1000X attenuation ratio, maximum differential voltage 7000 v, differential input impedance 2.5pF || 40MΩ, BNC interface.
DPB5700A High voltage differential probe, 100 MHz bandwidth, 100X/1000X attenuation ratio, maximum differential voltage 7000 v, differential input impedance 2.5pF || 40MΩ, BNC interface.
SCP5030 Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, SAPBus interface.
SCP5030A Current probe, DC-100 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, SAPBus interface.
SCP5150 Current probe, DC-12 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 150Arms/300Apk, jaw diameter of 20mm, powered by 12V adapter.
SCP5500 Current probe, DC-2 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 500Arms/750Apk, jaw diameter of 20mm, SAPBus interface.
CPL5100 Current probe, DC-600 kHz bandwidth, attenuation ratio of 10X/100X, current range of 50mA ~ 100Apk, powered by 12V adapter.
CP4020 Current probe, DC-200 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 20Arms/60Ap-p, 9V adapter for power supply.
CP4050 Current probe, DC-1 MHz bandwidth, 2X/20X attenuation ratio, maximum input 50Arms/140Ap-p, 9V adapter power supply.
CP4070 Current probe, DC-200 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 20Arms/60Ap-p, 9V adapter for power supply.
CP4070A Current probe, DC-300 kHz bandwidth, attenuation ratio of 10X/100X, maximum input of 70Arms/200Ap-p, 9V adapter for power supply.
CP6030 Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter.
CP6030A Current probe, DC-100 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter.
CP6150 Current probe, DC-12 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 150Arms/300Apk, jaw diameter of 20mm, powered by 12V adapter.
CP6500 Current probe, DC-5 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 500Arms/750Apk, jaw diameter of 20mm, powered by 12V adapter.
SAP4000P Power rail probe, DC-4 GHz bandwidth, 1.1X attenuation ratio, input dynamic range ±600mV, offset range ±24V, SAPBus interface.
SPL2016 16-channel logic probe (hardware), sampling rate and storage depth are determined by oscilloscope, which is suitable for SIGLENT technology SDS7000A, SDS6000A, SDS6000L, SDS5000X HD, SDS5000X, SDS3000X HD, SDS2000X HD and SDS2000X Plus models.
Other
Product Description
STB-3 Demo board Signals include various sine and square waves, AM, burst, and common serial bus signals.
DF2001A The phase calibration board, used in conjunction with power analysis software, is used to calibrate the phase difference generated by the voltage and current probes during transmission.
SYN64 64 Road synchronizer

Options
Trigger/decode Options
Product Description
SDS6000L-I2S I2S trigger & decode
SDS6000L-1553B MIL-STD-1553B trigger & decode
SDS6000L-FlexRay FlexRay trigger & decode
SDS6000L-CANFD CAN FD trigger & decode
SDS6000L-SENT SENT trigger & decode
SDS6000L-Manch Manchester decode option
Analysis Options
Product Description
SDS6000L-PA Power analysis option
SDS6000L-EJ Eye diagram and jitter analysis options
Other
Product Description
SDS6000L-FG Arbitrary waveform generator option

View more about Siglent SDS6000L Series Digital Oscilloscope on main site