Siglent SDS5000X Series Super Phosphor Oscilloscope

Bandwidth
1 GHz

Real time sampling rate
5 GSa/s

Channels
2/4 + EXT
 

Product Introduction
SIGLENT SDS5000X series digital oscilloscopes are designed for high-performance testing needs. The series offers an analog bandwidth of 350 MHz to 1 GHz, a sampling rate of up to 5 GSa/s, and a memory depth of 250 Mpts to ensure the capture of fine signal details. Supporting a wide range of advanced features such as baud graphs, power analysis software and multiple serial protocol triggering and decoding, they are ideal for engineers and researchers.

Key Features
  • Bandwidth:350 MHz, 500 MHz, 1 GHz
  • Real-time sampling rate:5 GSa/s
  • Memory depth:250 Mpts
  • Waveform capture rate:500,000 wfm/s (Sequence mode)
  • Mixed Signal Measurement (MSO)
 

Product advantage

Multi-touch, remote control

SDS5000X is equipped with a 10.1-inch touch screen, you can quickly adjust the waveform position, set the area trigger, parameter selection and setup. SDS5000X supports up to dozens of parameter measurements, and if you use the traditional knob to select, it will undoubtedly consume a lot of time, the touch screen selection, saving time and effort. In addition, SDS5000X also supports external mouse and keyboard.

Web remote control (Webserver) allows remote control of the oscilloscope without the need to install large-capacity drivers, and through the rear VGA interface, measurement results can be demonstrated. Meanwhile, SDS5000X is also equipped with free upper computer software, which supports SCPI programming commands.

Rich trigger types
The SDS5000X supports up to 11 intelligent trigger types to quickly trigger signals with different characteristics. For example, using Runt (under-amplitude triggering), you can quickly trigger at a set amplitude value.

For special signals that may require close to 20 setup steps with conventional trigger types, the SDS5000X adds area triggering to all trigger types. Complex signals can be triggered in “” one step “” by simply drawing the trigger zone box.

Trigger sources supported by the SDS5000X include 4 analog channels, 16 digital channels, EXT,EXT/5, AC Line.

Triggering and decoding of serial protocols covering various industries
The SDS5000X offers a wide range of serial protocol triggering and decoding across multiple industries.
I2C, SPI Embedded serial protocol triggering and decoding
UART PC Serial Protocol Trigger and Decode
CAN, CAN FD, LIN, FlexRay Automotive serial protocol triggering and decoding
I2S Audio serial protocol triggering and decoding
MIL-STD 1553B Flight System Serial Protocol Triggering and Decoding

Powerful Measurement Functions
The SDS5000X currently supports more than 55 parameter measurements. The advanced measurement function can measure 12 parameters at the same time and display the trend of parameter values in the form of a trend graph. The statistics function can be opened to display the current value of the parameter, average value, minimum value, maximum value, standard deviation and the number of statistics. And the distribution of parameter values can be displayed in the form of histogram, for example, when measuring clock jitter, you can visualize the distribution of jitter.

If you want to select a specific area for measurement, you can use the threshold measurement function and then move the cursor to select the area.

The source options for measurement include analog and digital channels as well as signals after Zoom, MATH waveforms, and Ref waveforms.

All-in-one oscilloscope
The SDS5000X combines a variety of functions in one unit, greatly saving space and providing more value to the user.

16-channel Logic Analyzer
25 MHz Isolated Signal Source Module, which can be used with the baud plot function for power loop response testing
Template Testing
Digital Multimeter
Baud Plot Function
Power Supply Analysis Software
Counter
Frequency Counter
 

Product parameter
Bandwidth
350 MHz, 500 MHz, 1 GHz
Channels
2+EXT, 4+EXT
Sampling Rate
5 GSa/s
Vertical Resolution
8-bit
Memory Depth
250 Mpts/ch
Screen Size
10.1-inch capacitive touch screen with resolution of 1024*600
Capture Rate
500,000 wfm/s
I/O
USB Host, USB Device, LAN, Pass/Fail, Trigger Out, 10 MHz In, 10 MHz Out, VGA
Trigger type
Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Qualifed, Zone
Serial triggering and decoding (standard)
I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B
Serial trigger and decode
Standard: I2C, SPI, UART, CAN, LIN
Optional: CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester (decode only), ARINC429 (decode only)
Digital channel
16 digital channels. Purchase 16-channel logic analyzer probe SPL2016, which can realize 16-channel digital channel acquisition function.
Waveform generator
The maximum output frequency is 25 MHz. You need to purchase an external signal source (SAG1021I) for use.
Probe (standard)
SP3050A, 500 MHz, 1 probe supplied for each channel
 

Models
Models Bandwidth Channels Vertical Resolution Sampling Rate Memory Depth Capture Rate
SDS5104X 1 GHz 4+EXT 8-bit 5 GSa/s 250 Mpts/ch 500,000 wfm/s
SDS5102X 1 GHz 2+EXT 8-bit 5 GSa/s 250 Mpts/ch 500,000 wfm/s
SDS5054X 500 MHz 4+EXT 8-bit 5 GSa/s 250 Mpts/ch 500,000 wfm/s
SDS5052X 500 MHz 2+EXT 8-bit 5 GSa/s 250 Mpts/ch 500,000 wfm/s
SDS5034X 350 MHz 4+EXT 8-bit 5 GSa/s 250 Mpts/ch 500,000 wfm/s
SDS5032X 350 MHz 2+EXT 8-bit 5 GSa/s 250 Mpts/ch 500,000 wfm/s
 

Configure your instrument

Standard Accessories
Probe (Standard)
Product Description
SP3050A Passive probe, 500 MHz bandwidth, 10X attenuation ratio, input impedance of 11pF || 10MΩ, with automatic identification function.
Other
Product Description
USB Cable USB-A to USB-B. Used to connect instrument to PC for communication.
Power cord The instrument comes standard with a power cord that conforms to the national standard of the user. Additional power cords in different regions can be purchased separately.
SDS5000X Quick guide SDS5000X Quick use guide for series oscilloscopes.
Optional Accessories
Probe
Product Description
SPL2016 16-channel logic probe (hardware), sampling rate and storage depth are determined by oscilloscope, which is suitable for SIGLENT technology SDS7000A, SDS6000A, SDS6000L, SDS5000X HD, SDS5000X, SDS3000X HD, SDS2000X HD and SDS2000X Plus models.
SAP1000 Active single-ended probe, 1 GHz bandwidth, 10X attenuation ratio, input impedance of 1.2pF || 1MΩ, offset range of ±12V, SAPBus interface.
SAP2500 Active single-ended probe, bandwidth of 2.5 GHz, attenuation ratio of 10X, input impedance of 1.1pF || 1MΩ, offset range of ±12V, SAPBus interface.
HPB4010 High voltage probe, DC-40 MHz bandwidth, 1000X attenuation ratio, input impedance 3pF || 100MΩ.
DPB1300 High voltage differential probe, 50 MHz bandwidth, 50X/500X attenuation ratio, maximum differential voltage ±1300V, differential input impedance 2pF || 10MΩ, BNC interface.
DPB4080 High voltage differential probe, 50 MHz bandwidth, 10X/100X attenuation ratio, maximum differential voltage 800 V, differential input impedance 1.2pF || 54MΩ, BNC interface.
DPB5150 High voltage differential probe, bandwidth of 70 MHz, attenuation ratio of 50X/500X, maximum differential voltage of ±1500V, differential input impedance of 2pF || 10MΩ, BNC interface.
DPB5150A High voltage differential probe, 100 MHz bandwidth, 50X/500X attenuation ratio, maximum differential voltage ±1500V, differential input impedance 2pF || 10MΩ, BNC interface.
DPB5700 High voltage differential probe, 70 MHz bandwidth, 100X/1000X attenuation ratio, maximum differential voltage 7000 v, differential input impedance 2.5pF || 40MΩ, BNC interface.
DPB5700A High voltage differential probe, 100 MHz bandwidth, 100X/1000X attenuation ratio, maximum differential voltage 7000 v, differential input impedance 2.5pF || 40MΩ, BNC interface.
SAP2500D Active differential probe, bandwidth of 2.5 GHz, attenuation ratio of 10X, differential input impedance of 1pF || 200kΩ, offset range of 8V, SAPBus interface.
TPA10 The active probe interface of SIGLENT oscilloscope SAPBus with TPA10 probe adapter can be used to adapt the active probe of Tektek TekProbe interface level II interface, which can supply power and DC bias for the probe without external power supply or other circuits.
SAP4000P Power rail probe, DC-4 GHz bandwidth, 1.1X attenuation ratio, input dynamic range ±600mV, offset range ±24V, SAPBus interface.
CP4020 Current probe, DC-200 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 20Arms/60Ap-p, 9V adapter for power supply.
CP4050 Current probe, DC-1 MHz bandwidth, 2X/20X attenuation ratio, maximum input 50Arms/140Ap-p, 9V adapter power supply.
CP4070 Current probe, DC-200 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 20Arms/60Ap-p, 9V adapter for power supply.
CP4070A Current probe, DC-300 kHz bandwidth, attenuation ratio of 10X/100X, maximum input of 70Arms/200Ap-p, 9V adapter for power supply.
CP6030 Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter.
CP6030A Current probe, DC-100 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter.
CP6150 Current probe, DC-12 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 150Arms/300Apk, jaw diameter of 20mm, powered by 12V adapter.
CP6500 Current probe, DC-5 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 500Arms/750Apk, jaw diameter of 20mm, powered by 12V adapter.
SCP5030 Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, SAPBus interface.
SCP5030A Current probe, DC-100 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, SAPBus interface.
SCP5150 Current probe, DC-12 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 150Arms/300Apk, jaw diameter of 20mm, powered by 12V adapter.
SCP5500 Current probe, DC-2 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 500Arms/750Apk, jaw diameter of 20mm, SAPBus interface.
CPL5100 Current probe, DC-600 kHz bandwidth, attenuation ratio of 10X/100X, current range of 50mA ~ 100Apk, powered by 12V adapter.
Other
Product Description
USB arbitrary waveform generator SAG1021I (isolated) USB arbitrary waveform generator module (isolated) integrates sine wave, square wave, triangular wave, pulse wave, noise, DC and 45 kinds of built-in arbitrary waves. Users can also edit arbitrary waveforms through EasyWave PC software.
STB-3 Demo board Signals include various sine and square waves, AM, burst, and common serial bus signals.
Portable soft BAG-S2 Portable soft BAG-S2,suitable forSSA3000X Plus, SSA3000X, SVA1000X,SDS5000X,SDS3000X HD,SDS2000X Plus series
DF2001A The phase calibration board, used in conjunction with power analysis software, is used to calibrate the phase difference generated by the voltage and current probes during transmission.
SDS5000X-RMK Rack mount kit for SDS5000X Digital Oscilloscopes.

Options
Trigger/decode Options
Product Description
SDS-5000X-1553B MIL-STD-1553B Trigger/decode option
SDS-5000X-CANFD CAN FD Trigger/decode option
SDS-5000X-FlexRay FlexRayTrigger/decode option
SDS-5000X-I2S IIS Trigger/decode option
SDS-5000X-SENT SENT Protocol Trigger and Decoding Kit (Software)
SDS-5000X-Manch Manchester protocol decoding (software)
SDS-5000X-ARINC ARINC429 trigger & decode
Bandwidth/Channel Upgrade Options
Product Description
SDS-5000X-4BW05 The bandwidth of 4-channel model is upgraded from 350 MHz to 500 MHz (note: 350 MHz model cannot be upgraded to 1 GHz model).
SDS-5000X-4BW10 The 4-channel model was upgraded from 500 MHz to 1 GHz.

View more about Siglent SDS5000X Series Super Phosphor Oscilloscope on main site