Details
Siglent SDS2000X Plus Series Super Phosphor Oscilloscope
Bandwidth
350 MHz
Real time sampling rate
2 GSa/s
Channels
2/4 + EXT
Product Introduction
SIGLENT’s SDS2000X Plus series Digital Storage Oscilloscopes are available in bandwidths of 350 MHz, 200 MHz and 100 MHz, have a maximum sample rate of 2 GSa/s, maximum record length of 200 Mpts/ch, and up to 4 analog channels + 16 digital channels mixed signal analysis ability.
Key Features
Product advantage
Excellent Operability
10-bit mode combined with Zoom shows you more details and less noise on the waveform.
The vertical and horizontal zoom feature of the SDS2000X Plus enable the user to pick a region and magnify the captured signal in order to conduct a more detailed analysis. Vertical zoom has an added advantage: The original vertical settings remain unchanged and the input stage won’t be overdriven. This means you can view more details of the waveform with minimal distortion.
Measurements for Parameters and Parameter Statistics
Parameter measurements includes 4 categories: horizontal, vertical, miscellaneous and channel delay providing a total of 50+ different types of measurements. Measurements can be performed within a specified gate period. Measurements on Math, Reference and History frames are supported.
Statistics shows the current value, maximum value, minimum value, standard deviation and mean value of up to 12 parameters simultaneously. Histogram is available to show the probability distribution of a parameter. Trend is available to show the parameter value vs. time. In addition, horizontal measurements can process up to 1000 signal edges within one single frame, thus greatly improving the test efficiency.
Power Loop Response Analysis (Bode Plot)
Stability is a very important indicator in power supply design. In general, stability measurement requires a special frequency response analyzer, but it is very expensive. Siglent offers an affordable solution: SDS2000X Plus oscilloscope and signal source Power loop measurement with standard Free Bode Plot II software.
· Higher measurement sensitivity and accuracy
· Variable excitation scan mode allowed for complex test scenarios of the power control loop test box
· User-friendly UI design
· List and cursor measurements, more intuitive
Product parameter
Models
Configure your instrument
Standard Accessories
Probe (Standard)
Other
Optional Accessories
Probe
Other
Options
Trigger/decode Options
Analysis Options
Bandwidth/Channel Upgrade Options
Bandwidth
350 MHz
Real time sampling rate
2 GSa/s
Channels
2/4 + EXT
Product Introduction
SIGLENT’s SDS2000X Plus series Digital Storage Oscilloscopes are available in bandwidths of 350 MHz, 200 MHz and 100 MHz, have a maximum sample rate of 2 GSa/s, maximum record length of 200 Mpts/ch, and up to 4 analog channels + 16 digital channels mixed signal analysis ability.
Key Features
- Bandwidth:100 MHz,200 MHz,350 MHz
- Real time sampling rate:Up to 2 GSa/s
- Memory depth:200 Mpts/ch
- Waveform Capture rate:Up to 500,000 wfm/s
Product advantage
Excellent Operability
- 10.1” display with 1024×600 resolution
- Capacitive touch screen, supports multi-touch gestures, traces can be moved or scaled efficiently by a finger touch
- Built-in web server supports remote control over the LAN port using a web browser
- External mouse and keyboard support
10-bit mode combined with Zoom shows you more details and less noise on the waveform.
The vertical and horizontal zoom feature of the SDS2000X Plus enable the user to pick a region and magnify the captured signal in order to conduct a more detailed analysis. Vertical zoom has an added advantage: The original vertical settings remain unchanged and the input stage won’t be overdriven. This means you can view more details of the waveform with minimal distortion.
Measurements for Parameters and Parameter Statistics
Parameter measurements includes 4 categories: horizontal, vertical, miscellaneous and channel delay providing a total of 50+ different types of measurements. Measurements can be performed within a specified gate period. Measurements on Math, Reference and History frames are supported.
Statistics shows the current value, maximum value, minimum value, standard deviation and mean value of up to 12 parameters simultaneously. Histogram is available to show the probability distribution of a parameter. Trend is available to show the parameter value vs. time. In addition, horizontal measurements can process up to 1000 signal edges within one single frame, thus greatly improving the test efficiency.
Power Loop Response Analysis (Bode Plot)
Stability is a very important indicator in power supply design. In general, stability measurement requires a special frequency response analyzer, but it is very expensive. Siglent offers an affordable solution: SDS2000X Plus oscilloscope and signal source Power loop measurement with standard Free Bode Plot II software.
· Higher measurement sensitivity and accuracy
· Variable excitation scan mode allowed for complex test scenarios of the power control loop test box
· User-friendly UI design
· List and cursor measurements, more intuitive
Product parameter
| Bandwidth 100 MHz, 200 MHz, 350 MHz |
Channels 2+EXT, 4+EXT |
| Sampling Rate 2 GSa/s |
Vertical Resolution 8 bit, optional 10-bit mode |
| Memory Depth 200 Mpts/ch |
Screen Size 10.1-inch capacitive touch screen with resolution of 1024*600 |
| Capture Rate 500,000 wfm/s |
Impedance (1 MΩ±2%) || (17 pF±2 pF) 50 Ω: 50 Ω±1% |
| Time scale 1.0 ns/div ~ 1000 s/div ROLL: ≥ 50 ms/div |
Trigger type Edge, Slope, Pulse, Window, Runt, Interval, Dropout, Pattern, Video and Serial |
| Serial trigger and decode Standard:IIC, SPI, UART, CAN, LIN Optional:CAN FD, FlexRay, IIS, MIL-STD-1553B,SENT,Manchester |
Digital channel 16 digital channels. Purchase 16-channel logic analyzer probe SPL2016, which can realize 16-channel digital channel acquisition function. |
| Math 2 traces 2 Mpts FFT, +, -, x, ÷, d/dt, ∫dt, √, Identity, Negation, |x|, Sign, ex, 10x, ln, lg, Interpolation, average, ERES, and formula editor |
Measurement More than 50 parameters,supports statistics with histogram, track and trend |
| I/O USB 2.0 Host x2, USB 2.0 Device, 10M/100M LAN, External trigger, Auxiliary output (TRIG OUT,PASS/FAIL) |
Max. Input voltage 1 MΩ ≤ 400 Vpk(DC + AC), DC~10 kHz 50 Ω ≤ 5 Vrms, ±10 V Peak |
| Waveform generator Built-in source, maximum output frequency 50 MHz. You need to purchase any waveform generator software option to use. |
Dimensions Length x Height x Width = 352 mm×224 mm×111 mm |
Models
| Models | Bandwidth | Channels | Vertical Resolution | Sampling Rate | Memory Depth | Capture Rate |
|---|---|---|---|---|---|---|
| SDS2102X Plus | 100 MHz | 2+EXT | 8 bit, optional 10-bit mode | 2 GSa/s | 200 Mpts/ch | 500,000 wfm/s |
| SDS2104X Plus | 100 MHz | 4+EXT | 8 bit, optional 10-bit mode | 2 GSa/s | 200 Mpts/ch | 500,000 wfm/s |
| SDS2204X Plus | 200 MHz | 4+EXT | 8 bit, optional 10-bit mode | 2 GSa/s | 200 Mpts/ch | 500,000 wfm/s |
| SDS2354X Plus | 350 MHz | 4+EXT | 8 bit, optional 10-bit mode | 2 GSa/s | 200 Mpts/ch | 500,000 wfm/s |
Configure your instrument
Standard Accessories
Probe (Standard)
| Product | Description |
| PP215 | Passive probe, 200 MHz bandwidth, 1X/10X attenuation ratio and input impedance of 13pF || 1MΩ/10MΩ. |
| SP2035A | Passive probe, bandwidth of 350 MHz, attenuation ratio of 10X, input impedance of 12pF || 10MΩ, with automatic identification function. |
| Product | Description |
| USB Cable | USB-A to USB-B. Used to connect instrument to PC for communication. |
| Power cord | The instrument comes standard with a power cord that conforms to the national standard of the user. Additional power cords in different regions can be purchased separately. |
| SDS2000X Plus Quickstart | Quick use guide of SDS2000X Plus series oscilloscopes. |
Optional Accessories
Probe
| Product | Description |
| SPL2016 | 16-channel logic probe (hardware), sampling rate and storage depth are determined by oscilloscope, which is suitable for SIGLENT technology SDS7000A, SDS6000A, SDS6000L, SDS5000X HD, SDS5000X, SDS3000X HD, SDS2000X HD and SDS2000X Plus models. |
| HPB4010 | High voltage probe, DC-40 MHz bandwidth, 1000X attenuation ratio, input impedance 3pF || 100MΩ. |
| DPB1300 | High voltage differential probe, 50 MHz bandwidth, 50X/500X attenuation ratio, maximum differential voltage ±1300V, differential input impedance 2pF || 10MΩ, BNC interface. |
| DPB4080 | High voltage differential probe, 50 MHz bandwidth, 10X/100X attenuation ratio, maximum differential voltage 800 V, differential input impedance 1.2pF || 54MΩ, BNC interface. |
| DPB5150 | High voltage differential probe, bandwidth of 70 MHz, attenuation ratio of 50X/500X, maximum differential voltage of ±1500V, differential input impedance of 2pF || 10MΩ, BNC interface. |
| DPB5150A | High voltage differential probe, 100 MHz bandwidth, 50X/500X attenuation ratio, maximum differential voltage ±1500V, differential input impedance 2pF || 10MΩ, BNC interface. |
| DPB5700 | High voltage differential probe, 70 MHz bandwidth, 100X/1000X attenuation ratio, maximum differential voltage 7000 v, differential input impedance 2.5pF || 40MΩ, BNC interface. |
| DPB5700A | High voltage differential probe, 100 MHz bandwidth, 100X/1000X attenuation ratio, maximum differential voltage 7000 v, differential input impedance 2.5pF || 40MΩ, BNC interface. |
| CPL5100 | Current probe, DC-600 kHz bandwidth, attenuation ratio of 10X/100X, current range of 50mA ~ 100Apk, powered by 12V adapter. |
| CP4020 | Current probe, DC-200 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 20Arms/60Ap-p, 9V adapter for power supply. |
| CP4050 | Current probe, DC-1 MHz bandwidth, 2X/20X attenuation ratio, maximum input 50Arms/140Ap-p, 9V adapter power supply. |
| CP4070 | Current probe, DC-200 kHz bandwidth, attenuation ratio of 20X/200X, maximum input of 20Arms/60Ap-p, 9V adapter for power supply. |
| CP4070A | Current probe, DC-300 kHz bandwidth, attenuation ratio of 10X/100X, maximum input of 70Arms/200Ap-p, 9V adapter for power supply. |
| CP6030 | Current probe, DC-50 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter. |
| CP6030A | Current probe, DC-100 MHz bandwidth, 1X/10X attenuation ratio, maximum input of 30Arms/50Apk, jaw diameter of 5mm, powered by 12V adapter. |
| CP6150 | Current probe, DC-12 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 150Arms/300Apk, jaw diameter of 20mm, powered by 12V adapter. |
| CP6500 | Current probe, DC-5 MHz bandwidth, attenuation ratio of 10X/100X, maximum input of 500Arms/750Apk, jaw diameter of 20mm, powered by 12V adapter. |
| Product | Description |
| DF2001A | The phase calibration board, used in conjunction with power analysis software, is used to calibrate the phase difference generated by the voltage and current probes during transmission. |
| SDS2000-RMK | Special rack mounting kit for SDS2000X and SDS2000X Plus series digital oscilloscopes. |
| Portable soft BAG-S2 | Portable soft BAG-S2,suitable forSSA3000X Plus, SSA3000X, SVA1000X,SDS5000X,SDS3000X HD,SDS2000X Plus series |
| STB-3 Demo board | Signals include various sine and square waves, AM, burst, and common serial bus signals. |
Options
Trigger/decode Options
| Product | Description |
| SDS2000XP-SENT | SENT Protocol Trigger and Decoding Kit (Software) |
| SDS2000XP-Manch | Manchester protocol decoding (software) |
| SDS2000XP-I2S | I2S trigger & decode |
| SDS2000XP-FlexRay | FlexRay trigger & decode |
| SDS2000XP-CANFD | CAN FD trigger & decode |
| SDS2000XP-1553B | MIL-STD-1553B Trigger/Decode Option |
| Product | Description |
| SDS2000XP-PA | Power analysis option |
| Product | Description |
| SDS2000XP-2BW03 | 100 MHz to 350 MHz bandwidth upgrade option (2 channels) |
| SDS2000XP-4BW02 | 100 MHz to 200 MHz bandwidth upgrade option (4 channels) |
| SDS2000XP-4BW03 | 200 MHz to 350 MHz bandwidth upgrade option (4 channels) |
| SDS2000XP-4BW05 | 350 MHz to 500 MHz bandwidth upgrade option (4 channels) |
View more about Siglent SDS2000X Plus Series Super Phosphor Oscilloscope on main site