Siglent SDG1000X Plus Series Function/Arbitrary Waveform Generator

Siglent SDG1000X Plus Series Function/Arbitrary Waveform Generator


Specifications
Details

Siglent SDG1000X Plus Series Function/Arbitrary Waveform Generator

Max Output Frequency
60 MHz

Max sampling rate
1 GSa/s

Vertical Resolution
16-bit
 

Product Introduction
SDG1000X Plus series is a high-performance waveform generator introduced by SIGLENT Technology to the market. Its EasyPulse technology ensures the high stability and low jitter of the output waveform, and its powerful waveform editing function can meet the needs of different application scenarios.

Key Features
  • Dual output channels, maximum 60 MHz output frequency, maximum 20 Vpp output amplitude
  • 1 GSa/s Sampling rate, 16-bit vertical resolution
  • Arbitrary wave length 8 Mpts/CH
  • Maximum 40 Mbps PRBS output
  • Multi-pulse output function
  • 4.3-inch display
 

Product Advantage

High-performance Sampling System

High resolution and sampling rates are critical for accurate signal simulation and analysis. The SDG1000X Plus series offers a high-performance sampling system with 16-bit vertical resolution and a 1 GSa/s sampling rate, delivering precise signal details and ensuring high fidelity. It is well-suited for applications requiring accurate signal generation, such as the development and testing of communication equipment.


8 Mpts/CH Arbitrary Waveform
The SDG1000X Plus supports 8 Mpts of waveform memory, enabling the generation of long-duration, complex modulated signals for high-precision testing. It accurately simulates modulated signals and pulse sequences for modern communication systems, ensuring system performance. It is also suited for high-speed chip testing in the semiconductor industry, where precise timing and amplitude control are critical for achieving test accuracy. Furthermore, researchers in the biomedical field can utilize it to simulate complex bioelectric signals, advancing the study of electrical signal transmission in living organisms and facilitating the development of medical devices.


PRBS code type output to help BER testing
Provides PRBS3 ~ PRBS32 multiple pattern outputs, the rate is arbitrarily adjustable between 10-6 bps ~ 40 Mbps, and the edge is arbitrarily adjustable between 10 ns ~ 1us.


Dual Pulse Generator for Easy Power Device Testing
The SDG1000X Plus incorporates multi-pulse output functionality with rise/fall times as low as 10 ns. Each pulse can be individually configured, allowing engineers to generate precise gate drive signals and measure switching parameters and dynamic characteristics of power devices. This functionality significantly enhances the testing efficiency and accuracy of power devices such as IGBTs and MOSFETs.


Webserver Remote Control
The built-in Webserver function offers engineers a convenient way to remotely control and configure the instrument via a network, simplifying testing workflows, particularly in environments that require frequent parameter adjustments.

 

Product parameter
Max Output Frequency
25 MHz, 30 MHz, 60 MHz
Sampling Rate
1 GSa/s
Vertical Resolution
16-bit
Waveform Length
8 Mpts
Channels
2
Output Frequency Resolution
1 μHz
Waveform
Sine,Square,Ramp,Pulse,Gaussian white noise,196 types of built-in Arb
Max.Amplitude
±10 V
I/O
Standard : USB Host, USB Device、LAN
Optional : GPIB (USB-GPIB adapter )
Modulation
AM、 FM、PM、FSK、ASK、DSB-AM、PWM、Sweep、Burst
 

Models
Models Max Output Frequency Sampling Rate Vertical Resolution Waveform Length Channels
SDG1022X Plus 25 MHz 1 GSa/s 16-bit 8 Mpts 2
SDG1032X Plus 30 MHz 1 GSa/s 16-bit 8 Mpts 2
SDG1062X Plus 60 MHz 1 GSa/s 16-bit 8 Mpts 2
 

Configure your instrument

Standard Accessories
Universal accessories
Product Description
USB Cable USB-A to USB-B. Used to connect instrument to PC for communication.
Power cord The instrument comes standard with a power cord that conforms to the national standard of the user. Additional power cords in different regions can be purchased separately.
BNC Crocodile clip cable One BNC to alligator clip cable is provided as standard.
SDG1000X Plus Quick Start Quick-use guide as standard for the instrument.

Optional Accessories
Universal accessories
Product Description
USB-GPIB Adapter Expand the instrument’s USB interface into a GPIB interface. Using GPIB commands allows for easier execution of various operational tasks. The USB interface adheres to the USB 2.0 specification, while the GPIB interface complies with the IEEE 488.2 standard.
SPA1010 Power Amplifier SPA1010 The power amplifier can be matched with SIGLENT full series function/arbitrary waveform generator products to realize the power amplification of its signal output.
20dB Attenuator Used for 20dB attenuation of signal power output by signal source, BNC connector
BNC Coaxial Cable Double BNC connector coaxial cable
SDG/SDM-RMK Rack installation The rack mounting option is designed to mount the instrument to the standard 19-inch rack specified by EIA, and it is compatible with SIGLENT full series SDG function/arbitrary waveform generator and SDM series digital multimeter.

View more about Siglent SDG1000X Plus Series Function/Arbitrary Waveform Generator on main site