Details
Key features
- 384 x 288 infrared resolution
- Asset Tagging
- Touchscreen IR Fusion™
- IS3 and AVI video recording
- Measure up to 550 °C
- Dew-point calculation
Product overview: TiS75+ Thermal Camera
Be proactive instead of reactive
Take your plan for a proactive maintenance (PM) program and turn it into reality. To get started, you need features that make it easy to set up your image organization and inspection routines. With the TiS75+ you’re well on your way to implementing a successful PM program.
-
Asset Tagging allows you to easily compare asset images over time.
-
Scanning the QR code on each asset creates a timeline of your inspections.
-
Use the time saved (25% on average spent organizing thermal images) to analyze asset images for trends, diagnosing issues and fixing problems before they become failures.
Step up to the TiS75+
This new Fluke thermal camera stays true to our mantra of giving the customer more than they paid for. The Fluke TiS75+ offers features to help you tackle almost anything you’ll face in the field. In addition to the features noted above, the TiS75+ also includes:
- IS3 and AVI video recording
- Data streaming
- 384 x 288 thermal resolution
- High temperature range—up to 550 °C
- Dew-point calculation
- Thermal imager
- AC power supply (including universal AC adapters)
- Two-bay smart battery charger
- Two rugged lithium ion smart batteries
- USB cable
- 4 GB micro SD card
- Rugged hard carrying case with soft transport bag and adjustable hand strap
- Available by free download: Fluke Connect™ software and user manual
Specifications: TiS75+ Thermal Camera
Key Features | TiS75+ |
Infrared resolution | 384 x 288 (110,592 pixels) |
IFOV | 1.91 mRad |
Field of view | 42° x 30° |
Minimum focus distance | 0.15 m |
Focus system | Manual focus |
Wireless connectivity | Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi and LAN (where available) |
Fluke Connect app compatible | Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing |
Fluke Connect Assets optional software | Yes*, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location |
Asset Tagging | Scan a QR code to automatically organize and file thermal images with Fluke Connect™ |
IR-Fusion technology | AutoBlend continuous 0 % to 100 %. Adds the context of the visible details to your infrared image |
Picture-InPicture (PIP) | Yes |
Display | 3.5" (8.9 cm landscape) touchscreen 640 x 480 LCD |
Ergonomic design | Designed for one-handed use |
Thermal sensitivity | 40mk |
Level and span | Smooth auto and manual scaling |
Fast auto-rescale in manual mode | Yes |
Minimum span (in manual mode) | 3° °C (4.5 °F) |
Minimum span (In auto mode) | 5°C (9.0 °F) |
Built-in digital camera (visible light) | 640 x 480 |
Frame rate | 9 Hz or 27 Hz models |
Dew point calculation | Yes |
Data storage and image capture | |
Internal memory | ∼500 images |
External memory | ≥4 GB SD card (>1000 images) |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
Image file formats | Non-radiometric BMP or JPEG or fully-radiometric is2 |
Memory review | Yes |
Software | Fluke Connect software—full analysis and reporting software with access to the Fluke Connect |
Analyze and store radiometric data on a PC | Yes |
Export file formats with Fluke Connect software | is2, BMP, GIF, JPEG, PNG, TIFF |
Voice annotation | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device. |
IR-PhotoNotes | Yes. Up to 3 extra user-selectable visible light image capture to be included in IS2 file. |
Text annotations | After IS2 capture, user can type in a note using on-screen keyboard. |
Video recording and formats | Standard and radiometric video. Up to 5 minute recording length. avi and is3 |
Remote control operations | No |
Auto capture (temperature and interval) | Yes. User-selectable time interval for capturing IS2 or Jpeg files. |
Battery | |
Batteries (field-replaceable, rechargeable) | Lithium-ion rechargeable battery |
Battery life | ≥3.5 hours continuous without WiFi (Actual life depends on settings and usage) |
Battery charging time | ≤2.5 hours to full charge |
Battery charging system | Ti SBC3B Two-Bay Battery Charger or in-Imager charging. |
AC operation | AC operation with included power supply, universal adapters included Output: 15 VDC, 2 A |
Power saving | User-selectable sleep and power off |
Temperature measurement | |
Temperature range (not calibrated below -10 °C) | -20 °C to 550°C (not calibrated below -10 °C) |
Accuracy | ±2 °C or 2 % (whichever is greater) at 25 °C ambient temperature |
On-screen emissivity correction | Yes, “top ten” material list plus numerical adjustment between 0.01 and 1.00 |
Color palettes | |
Standard palettes | 6 |
General specifications | |
Color alarms | Yes. User-selectable hot and cold point and internal/external range color alarms. Modifies palettization of IR image by limiting which pixels are drawn using palette colors based on the pixel temperature. |
Infrared spectral band | ~8-14μm |
Operating temperature | -10 °C to 50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to 50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Spot temperature | Center spot (unmovable) |
User-definable spot markers | Yes, 5 user-adjustable spot markers for a single pixel each. Position is adjustable. Temperature value for marker shown on screen. User can choose to switch display on/off for each marker. |
User defined measurement boxes | Yes, 5 user-adjustable rectangles. Size and position are adjustable. Rectangle statistics shown on screen: Min, Max, Average temperature. User can choose to switch display on/off for each marker. |
Hard case | Rugged hard carrying case with soft transport bag, including adjustable strap |
Safety standards | IEC 61010-1: Pollution Degree 2 |
Electromagnetic combability | IEC 61326-1: Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A |
Australian RCM | RCM IEC 61326-1 |
US FCC | 47 CFR 15 Subpart C Sections 15.207, 15.209, 15.249 |
Vibration | 10 Hz to 150 Hz, 0.15 mm, IEC 60068-2-6 |
Shock | 30 g, 11 ms, IEC 60068-2-27 |
Drop | Engineered to withstand 2m drop |
Sized (H x W x L) | ∼(26.7 cm x 10.1 cm x 14.5 cm) ∼ (10.5 in x 4.0 in x 5.7 in) |
Weight (battery included) | 0.885 kg (1.95 lbs) |
Enclosure rating | IP54 |
Warranty | Two-years (standard) |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
RoHS compliant | Yes |
Models: TiS75+ Thermal Camera
FLK-TIS75+ 27HZ
Fluke TiS75+ Thermal Camera 27HZ
Includes:
- Thermal imager
- AC power supply (including universal AC adapters)
- Two-bay smart battery charger
- Two rugged lithium ion smart batteries
- USB cable
- 4 GB micro SD card
- Rugged hard carrying case with soft transport bag and adjustable hand strap
- Available by free download: Fluke Connect™ software and user manual
FLK TiS75+ 9HZ
Fluke TiS75+ Thermal Camera 9HZ
Includes:
- Thermal imager
- AC power supply (including universal AC adapters)
- Two-bay smart battery charger
- Two rugged lithium ion smart batteries
- USB cable
- 4 GB micro SD card
- Rugged hard carrying case with soft transport bag and adjustable hand strap
- Available by free download: Fluke Connect™ software and user manual