Details
HIOKI MR8740T Memory Hicorder
Max. 108 Analog Channels, Reduce Inspection Data Transfer Time to Zero
OVERVIEW
The MR8740T (MR8740-50) is rack-mountable data acquisition system that delivers high-speed, multi-channel measurements over maximum of 108 channels. Generate simulated signals and record at the same time using plug-and-play input units, making the waveform recorder ideal for evaluating multi-signal devices such as vehicle electronic control units (ECU).
Key Features
Key Features
- Ideal for multipoint inspection of high performance boards such as ECU
- 108ch analog to 96ch analog + 48ch logic input
- Reduce time required to save to external media to max.1/100 compared with conventional method
- 20 MS/s simultaneous sampling on all channels
- Safe measurement with all analog inputs isolated
- Supports 4K monitor to display multi-channel waveforms without overlapping
- Measure 4 channels with 1 unit (4 ch analog Unit U8975, 4 ch DVM Unit U8991)
- Generate constant voltage, constant current, and simulated resistance (VIR Generator Unit U8794)
Note: A special option such as an input unit is required for the main unit. Please purchase various common options such as input cord separately.
FEATURES
ECU Testing
ECUs are connected to a large number and wide variety of sensors. The MR8740T can be installed with signal generation unit to simulate these sensors. By measuring the simulation results with a measurement unit at the same time, you can perform all steps from signal generation to measurement with a single device. The U8794 VIR GENERATOR UNIT also offers resistance output to enable thermistor circuit testing.
Ideal for testing that requires simulated signals
When used as an ECU testing device, generate simulated signals from various sensors, which is indispensable for testing electronic parts and maintaining equipment. Record signals captured by various sensors to identify air flow, throttle, torque, speed, vibration, humidity, etc.
SPECIFICATIONS
Basic specifications
Accuracy guaranteed: 1 year
FEATURES
ECU Testing
ECUs are connected to a large number and wide variety of sensors. The MR8740T can be installed with signal generation unit to simulate these sensors. By measuring the simulation results with a measurement unit at the same time, you can perform all steps from signal generation to measurement with a single device. The U8794 VIR GENERATOR UNIT also offers resistance output to enable thermistor circuit testing.
Ideal for testing that requires simulated signals
When used as an ECU testing device, generate simulated signals from various sensors, which is indispensable for testing electronic parts and maintaining equipment. Record signals captured by various sensors to identify air flow, throttle, torque, speed, vibration, humidity, etc.
SPECIFICATIONS
Basic specifications
Accuracy guaranteed: 1 year
Number of input units | Max. 27 slots |
Number of channels | [Using the U8975] Max. 108 ch analog, or 96 ch analog + 48 ch logic (when used in combination with U8975 + 8973) [Using the 8966] Max. 54 ch analog, or 48 ch analog + 48 ch logic (when used in combination with 8966 + 8973) *Logic unit 8973 is limited to slots 25 to 27, up to 3 units. *Analog unit channels are isolated from each other and from chassis. Logic unit channels share a common GND with chassis. |
Measurement ranges | 100 mV to 400 V f.s., 12 ranges, resolution : 1/2000 of range (when using 8966) 4 V to 200 V f.s., 6 ranges, resolution : 1/32000 of range (when using U8975) 100 mV to 1000 V f.s., 5 ranges, resolution : 1/1000 000 of range (when using MR8990) 1 V, 10 V, 100 V f.s., 3 ranges, resolution : 1/1000 000 of range (when using U8991) |
Max. allowable input | 400 V DC (when using 8966; upper limit voltage that can be applied between input terminals without damage) |
Max. rated voltage to earth | Z300 V AC/DC (input and instrument are isolated; between input channels and chassis; upper limit voltage that can be applied between input channels without damage) |
Frequency characteristics | DC to 5 MHz (-3 dB, when using 8966) |
Max. sampling speed | 20 MS/s, all ch simultaneous, external sampling: 10 MS/s |
Measurement functions | Memory (high-speed recording) |
Memory capacity | Total of 1 G Word installed, 16 MW/ch (when using 8966), 8 MW/ch (when using U8975 or MR8990), 4 MW/ch (when using U8991) |
Internal storage | SSD 480 GB |
Removable storage | USB memory stick ×8 |
Monitor output | VGA, HDMI, Display Port, Recommended resolution 1920 × 1080 dot or more |
External interfaces | [LAN] 1000 BASE-T, 100 BASE-TX, 10 BASE-TX (2 port) (DHCP and DNS support, FTP server/cliant, HTTP server) [USB] USB 3.0 Series A receptacle × 4, USB 2.0 ×4 |
Power supply | 100 to 240 V AC, 50/60 Hz (400 VA max.) |
Dimensions and mass | 426 mm (16.77 in)W × 177 mm (6.97 in)H × 505 mm (19.88 in)D, 14.0 kg (493.8 oz) (main unit only) |
Included accessories | Power cord ×1,Quick Start Manual (booklet) ×1, Instruction Manual (detailed edition) (CD-R) ×1, application disk (CD-R) ×1, blank panel (blank slot only), rack installation hardware |